Serial-Ethernet-USB Based Remote DAS modules

Wholesale Trader of a wide range of products which include et-7051 standard digital module with tcp, modbus i/o data acquisition module series, et-7026 standard multifunction module with tcp, m-7024 standard analog output module with rs485, et-7017 standard analog input module with tcp and et-7024 standard analog output module with tcp.

ET-7051 Standard Digital Module With TCP

Request Callback

₹ 25000 / Piece Get Latest Price

Product Brochure
Model Name/NumberET-7051
Dimensions72 mm x 123 mm x 35 mm
Humidity10 ~ 90% RH, non-condensing
Storage Temperature-30 deg C - +80 deg C
Operating Temperature-25 deg C - +75 deg C
InstallationDIN-Rail or Wall mounting
Consumption2.2 W
Ethernet Port10/100 Base-TX with Auto MDI/MDI-X

Feature:

  • Power over Ethernet (PoE)
  •  Daisy-Chain Ethernet Cabling
  •  LAN Bypass
  •  Communication Security
  • Support for both Modbus TCP and Modbus UDP Protocols
  • Built-in I/O
  • Dual Watchdog
  • Highly Reliable Under Harsh Environment
  •  I/O Pair Connection
  • Power-on Value and Safe Value
  • Led indicators for DIO status
  • Reset Button
  • Two pair of power input pins

Model with IO Specification:

                                          Digital I/O

Model

                 DI

                       DO

Channel

Type

Sink/Source

Channel

Type

Sink/Source

ET-7042

-

-

-

16

Open Collector

Sink

ET-7051

16

Wet

Sink, Source

-

-

-

     ET-7052

8

Wet

Sink, Source

8

Open Collector

Source

ET-7044

8

Wet

Sink, Source

8

Open Collector

Sink


Modbus I/O Data Acquisition Module Series

Request Callback

₹ 25000 / Unit Get Latest Price

Product Brochure
CPU32-bit ATMEL ARM, 72MHZ
Working Environment40 Deg -85 Deg C
ProtectionIP20
Watchdog1.5 m guard
Port type1RS485 & 1RS232
Precision0.1%16 bit
Refresh rate0.01m

CWT Modbus IO module series with multi-channel DI/DO/AI/PT100 input. widely used in buildings, HVAC, fire, water, petrochemical, environmental protection and other industries, for most systems integrators and automation companies, it is a highly cost-effective, reliable data acquisition module. This module is designed for the whole industry, power supply, signal inputs and outputs, RS232 and RS485 interface (option Ethernet), interference protection designed to ensure data accuracy and reliability. RS485 communication interface performs MODBUS RTU protocol, can be directly connected with the various types of PLC, DCS system, operator panel and a variety of configuration software.

System parameters:

CPU

32-bit ATMEL ARM, 72MHZ

OS

GCOS???10ms scheduling mechanism

Power

7-35VDC @2W, power supply reverse protection, isolation design

Installation

DIN rail mounting or screw fixing

Working Environment

-40??????85??????5%???95%RH (non-condensing)

Protection

IP20

Watchdog

1.5m guard

Analog input:

Input type

4~20mA option: 0~20mA/0~5/1~5/0~10V

Precision

0.1 16 bit

Refresh rate

0.01m

Digital input:

ON signal level

5-30VDC 6mA@24VDC

OFF signal level

0-3VDC

Protection

optocoupler isolation, 2500V lightning protection, overvoltage, overcurrent protection

sample rate

0.01m

Digital output:

Output type

normal open relay or Transistor output

Isolation

optocoupler isolation& relay isolation

Resistive load

5A/250VAC 5A/30VDC

Response time

≤0.01s

PT100 Input:

Precision

0.1

Measure range

-200 to 320

ET-7026 Standard Multifunction Module with TCP

Request Callback

₹ 30000 / Piece Get Latest Price

Product Brochure
Model Name/NumberET-7026
Accuracy+/- 0.1% of FSR
InstallationDIN-Rail or Wall mounting
Dimensions72 mm x 123 mm x 35 mm
Max Load Current700 mA/Channel
Current Load Resistance500 Ohms
Resolution12 bit
Open Wire for Current Output20 mA
Output Channels2

Feature:

  • Power over Ethernet (PoE)
  • Daisy-Chain Ethernet Cabling
  • LAN Bypass
  • Communication Security
  • Support for both Modbus TCP and Modbus UDP Protocols
  • Built-in I/O
  • Dual Watchdog
  • Highly Reliable Under Harsh Environment 
  • I/O Pair Connection
  • Power-on Value and Safe Value
  • Led indicators for DIO status
  • Reset Button
  • Two pair of power input pins

Model with IO Specification:

Multifunction I/O

Model

AI

AO

DI/Counter

DO

Channel

Voltage &
Current Input

Channel

Voltage &
Current Output

Channel

Channel

ET-7026

 

6

+/- 500 mV, +/- 1 V,
+/- 5 V, +/-10 V,0 ~ 20 mA,+/- 20 mA,4~20mA

 

2

0 ~ 5 V,+/- 5 V,       0 ~ 10 V,+/- 10 V,
0 ~ 20 mA,4 ~ 20mA

 

2

 

2

ET-7016

 

2

+/- 15 mV, +/- 50 mV,
+/- 100 mV, +/- 500 mV,+/- 1 V, +/- 2.5 V,
0 ~ 20 mA,+/- 20 mA, 4 ~ 20mA

 

1

 

0 ~ 10 V

 

2

 

2

ET-7002

 

3

+/- 150 mV, +/- 500 mV,+/- 1V, +/- 5 V, +/- 10 V, +0 ~ +20 mA,+/- 20 mA,  4 ~ 20mA

-

-

 

6

 

3


 

 

M-7024 Standard Analog Output Module With RS485

Request Callback

₹ 32000 / Piece Get Latest Price

Product Brochure
Model Name/NumberM-7024
Humidity5 to 95% RH, non-condensing
Storage Temperature-40 to 85 deg C
Power Consumption2.4 W
LED Display1 LED as Power/ Communication indicator
Baud Rate115200 bps
Accuracy+/-0.1% of FSR
Output Channels4 Channels
Output Type20 mA
Resolution14 bit
Operating Temperature25 to 75 Deg C
Feature:
  • RS-485 Industrial Multi-Drop Network
  • I/O type and Range Programmable
  •  Easy Mounting and Connection
  • Rugged Industrial Environmen
  • Programmable Power-on Value and Safe Value
  • Advanced DI Functions

            DI Latch Function
            Low Speed Counter

  • Overvoltage Protection
  • Open Wire Detection
  • Over-current Protection
  • Virtual Channel to Channel Isolation
  • Common Voltage Protection
  • ESD Protection
  • Dual Communication Protocols

Model with IO Specification:

Analog Output

 

Model

                                             AO

 

 

Channel

Voltage Output

Current Output

DO Channel

DI Channel

M-7022

2

0 ~ +5 V,
0 ~ +10 V

0 ~ +20 mA,
+4 ~ +20 mA

-

-

M-7024R

4

4

0 ~ +5 V,
0 ~ +10 V,
±5 V, ±10 V;

0 ~ +20 mA,
+4 ~ +20 mA

-

5

M-7024U(D)

4

4

M-7028(D)

8

0 ~ +5 V,
0 ~ +10 V,
±5 V, ±10 V

0 ~ +20 mA,
+4 ~ +20 mA

-

-


ET-7017 Standard Analog Input Module With TCP

Request Callback

₹ 28000 / Piece Get Latest Price

Product Brochure
Model Name/NumberET-7017
Storage Temperature-30 deg C - +80 deg C
Humidity5 - 90% RH, non-condensing
InstallationDIN-Rail or Wall mounting
Dimensions72 mm x 123 mm x 35 mm
Power Consumption0.10 A, 24 VDC Max
Ethernet1500 VDC
SRAM512 KB
Common Mode Rejection86 dB Min

Feature:

  • Power over Ethernet (PoE)
  •  Daisy-Chain Ethernet Cabling
  •  LAN Bypass
  •  Communication Security
  • Support for both Modbus TCP and Modbus UDP Protocols
  • Built-in I/O
  • Dual Watchdog
  • Highly Reliable Under Harsh Environment
  •  I/O Pair Connection
  • Power-on Value and Safe Value
  • Led indicators for DIO status
  • Reset Button
  • Two pair of power input pins

Model with IO Specification: 

                                   Analog Input

Model

                         AI

DO

Channel

Voltage & Current -  Input

Sensor Input

Channel

ET-7017

8

+/-150 mV, +/-500 mV, +/-1 V,     +/-5 V, +/-10 V, +/-20 mA,
0 ~ 20 mA, 4 ~ 20 mA

-

4

ET-7018Z

10

+/-15 mV, +/-50 mV, +/-100 mV,
+/-500 mV, +/-1 V, +/-2.5 V
+/-20 mA, 0~20 mA, 4~20 mA

Thermocouple:
J, K, T, E, R, S, B, N, C, L, M, LDIN43710

6

ET-7217-10

10

+/-150 mV, +/-500 mV, +/-1 V,
+/-5 V, +/-10 V, +/-20 mA,
0 ~ 20 mA, 4 ~ 20 mA

-

-


ET-7024 Standard Analog Output Module With TCP

Request Callback

₹ 30000 / Piece Get Latest Price

Product Brochure
Humidity10 ~ 90% RH, Non-condensing
Storage Temperature-30-+80 deg C
InstallationDIN-Rail or Wall mounting
Dimensions72 mm x 123 mm x 35 mm
Consumption4.2 W
Powered from Terminal Block30 VDC
Current Load Resistance500 Q
Max. Input Frequency100 Hz
Model NumberET-7024

Feature:

  • Power over Ethernet (PoE)
  •  Daisy-Chain Ethernet Cabling
  •  LAN Bypass
  •  Communication Security
  • Support for both Modbus TCP and Modbus UDP Protocols
  • Built-in I/O
  • Dual Watchdog
  • Highly Reliable Under Harsh Environment
  •  I/O Pair Connection
  • Power-on Value and Safe Value
  • Led indicators for DIO status
  • Reset Button
  • Two pair of power input pins

Model with IO Specification:

                                            Analog Output

Model

                                    AO

Channel

Voltage Output

Current Output

ET-7028

8

-0 ~ 5 V, +/- 5 V,
0 ~ 10 V, +/- 10 V

0 ~ 20 mA,
4 ~ 20 mA


M-7026 Standard Multifunction Module with RS485

Request Callback

₹ 30000 / Piece Get Latest Price

Product Brochure
Model Name/NumberM-7026
Storage Temperature-40 to +85 Degree C
InterfaceRS-485
Baud Rate115200 bps
ProtocolModbus RTU,DCON
Humidity10 to 95% RH,Non-condensing
Operating Temperature-25 to +75 DegreeC
InstallationDIN-Rail or Wall Mounting
Dimensions123 mm x 72 mm x 35 mm
Features:
  • Multifunction (6 AI, 2 AO, 3 DI and 3 DO)
  • Supports Fast Mode and Normal Mode
  • Individual Channel Configuration
  • Open Wire Detection for Current Output
  • Overload and Short Circuit Protection for Digital Output
  • Configurable Power-on Value Settings
  • Configurable Safe Value Settings
  • 240 Vrms Overvoltage Protection for Voltage Input
  • Jumper Selectable Voltage or Current Input/Output
  • Dual Watchdog
  • ±4 kV Contact ESD Protection
  • Wide Operating Temperature Range: -25 ~ +75°C

Model with IO Specification:

                                            Multifunction I/O

Model

        AI

       AO

       DO

DI/Counter

CH

V&I- I/P

Ch

V/I -O/P

Ch

Type

Ch

Type

   M-7002

  4

±150 mV, ±500 mV, ±1 V,±5 V, ±10 V, ±20 mA,
0 ~ 20 mA,      4 ~ 20 mA

-

-

 4

Power Relay

5

Wet

 

M-7026

 

6

 

2

0 ~ +5 V,
0 ~ +10 V,
±5 V, ±10 V
+4 ~ +20 mA

 

3

Open Collector

 

3

 

Dry

M-7051D Standard Digital Module With RS485

Request Callback

₹ 20000 / Piece Get Latest Price

Product Brochure
Model Name/NumberM-7051D
InterfaceRS-485
Baud Rate115200 bps
Humidity10-95% RH
Storage Temperature-40-+85 deg C
Operating Temperature-25-+75 deg C
Dimension72 X 123 X 35 mm
InstallationDIn Rail or Wall Mounting

Feature:

  • RS-485 Industrial Multi-Drop Network
  • I/O type and Range Programmable
  • Easy Mounting and Connection
  • Rugged Industrial Environmen
  • Programmable Power-on Value and Safe Value
  • Advanced DI Functions
           DI Latch Function                                        Low Speed Counter
  • Overvoltage Protection
  • Open Wire Detection
  • Over-current Protection
  • Virtual Channel to Channel Isolation
  • Common Voltage Protection
  • ESD Protection
  • Dual Communication Protocols

Model with IO Specification:

                                      Digital I/O

   Model      

     DO Channel

               DI Channel

  M-7045D

             16

                    -

  M-7055D

              8

                     8

  M-7051D

              -

                    16

 M-7052D

              -

                      8


X

Contact Us

R Krishnan (CEO)
Nimbus Technologies
Globe Estate, Plot No. C-9, Unit No. 225, 2nd Floor, New Kalyan Road, Near Vikas Nakka, MIDC Industrial Area, Phase 1, Manpada, Khambalpada, Near Tata Power House Co.
Dombivli - 421204, Thane, Maharashtra, India

Get Directions
Send Email
Share: